Position switch, Rounded plunger, Basic device, expandable, 1 N/O, 1 NC, Cage Clamp, Black, Insulated material, -25 - +70 °C
Position switch, Part group reference: LS(M)-…, Product range: Rounded plunger, Degree of Protection: IP66, IP67, Features: Basic device, expandable, Ambient temperature: -25 - +70 °C, Contacts N/O = Normally open: 1 N/O, Contacts N/C = Normally closed: 1 NC, Notes: = safety function, by positive opening to IEC/EN 60947-5-1, Positive opening (ZW): yes, Colour Enclosure covers: Black, Housing: Insulated material, Connection type: Cage Clamp, Cage-Clamp is a registered trademark of Wago Kontakttechnik, 32432 Minden, Germany., Accessories for the Cage-Clamp terminals from Wago:power comb, gray, Wago Article No. 264-402, Standards: IEC/EN 60947
General specifications
Product name
Eaton Moeller® series LS Position switch
Part no.
LS-11-SW
EAN
4015082720063
Product Length/Depth
33.5 millimetre
Product height
76.5 millimetre
Product width
31 millimetre
Product weight
0.05 kilogram
Certifications
CSA-C22.2 No. 14
CSA File No.: 012528
CE
CSA
IEC/EN 60947
UL Category Control No.: NKCR
UL 508
CSA Class No.: 3211-03
UL File No.: E29184
UL
IEC/EN 60947-5
CSA File No.: 012528
CE
CSA
IEC/EN 60947
UL Category Control No.: NKCR
UL 508
CSA Class No.: 3211-03
UL File No.: E29184
UL
IEC/EN 60947-5
Product Tradename
LS
Product Type
Position switch
Product Sub Type
None
Features & Functions
Electric connection type
Cable entry metrical
Enclosure color
Black (Cover)
Enclosure material
Insulated material
Plastic
Plastic
Features
Positive opening
Expandable
Forced opening
Expandable
Forced opening
Switch function type
Slow-action switch
General information
Connection type
Cage Clamp
Degree of protection
NEMA Other
IP66/IP67
IP66/IP67
Lifespan
8,000,000 mechanical Operations
Operating frequency
6000 Operations/h
Overvoltage category
III
Pollution degree
3
Product category
Rounded plunger
Rated impulse withstand voltage (Uimp)
4000 V AC
Repetition accuracy
0.15 mm (Contacts/switching capacity)
Suitable for
Safety functions
Type
Safety position switch
Ambient conditions, mechanical
Mounting position
As required
Shock resistance
25 g, Standard-action contact, Mechanical, Half-sinusoidal shock 20 ms
Temperature resistance
100 °C, Contact temperature of roller head
Climatic environmental conditions
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
70 °C
Climatic proofing
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78
Damp heat, constant, to IEC 60068-2-78
Terminal capacities
Terminal capacity (flexible with ferrule)
1 x (0.5 - 1.5) mm²
Terminal capacity (solid)
1 x (0.5 - 2.5) mm²
Electrical rating
Rated conditional short-circuit current (Iq)
1 kA
Rated insulation voltage (Ui)
400 V
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V
6 A
Rated operational current (Ie) at AC-15, 24 V
6 A
Rated operational current (Ie) at AC-15, 380 V, 400 V, 415 V
4 A
Rated operational current (Ie) at DC-13, 110 V
0.6 A
Rated operational current (Ie) at DC-13, 125 V
0.8 A
Rated operational current (Ie) at DC-13, 220 V, 230 V
0.3 A
Rated operational current (Ie) at DC-13, 24 V
3 A
Short-circuit protection rating
Max. 6 A gG/gL, Fuse, Contacts
Supply frequency
Max. 400 Hz, Contacts
Actuator
Actuating force at beginning/end of stroke
1.0 N/8.0 N
Actuating torque of rotary drives
0.2 N·m
Actuator type
Plunger
Operating speed
Max. 1/0.5 m/s (with DIN cam, mechanical actuation)
For angle of actuation α = 0°/30°
For angle of actuation α = 0°/30°
Contacts
Control circuit reliability
1 failure per 5,000,000 switching operations (statistically determined, at 5 V DC/1 mA)
1 failure per 10,000,000 switching operations (Statistically determined, at 24 V DC/5 mA)
1 failure per 10,000,000 switching operations (Statistically determined, at 24 V DC/5 mA)
Number of contacts (change-over contacts)
0
Number of contacts (normally closed contacts)
1
Number of contacts (normally open contacts)
1
Safety
Explosion safety category for gas
None
Explosion safety category for dust
None
Design verification
Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0.17 W
Rated operational current for specified heat dissipation (In)
6 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Technical data ETIM 9.0
Sensors (EG000026) / Interruptor de posición individual (EC000030)
Tecnología electrónica, de automatización y de mando de procesos / Sensórica binaria, sens. orientada a la seguridad, tec. de medición de fabr. / Conmutador de posición orientado a la seguridad / Conmutador individual de posición orientado a la seguridad (ecl@ss13-27-27-26-01 [AKE640018])
Width sensor
31 mm
Diameter sensor
0 mm
Height of sensor
61 mm
Length of sensor
33.5 mm
Rated operation current Ie at AC-15, 24 V
6 A
Rated operation current Ie at AC-15, 125 V
6 A
Rated operation current Ie at AC-15, 230 V
6 A
Rated operation current Ie at DC-13, 24 V
3 A
Rated operation current Ie at DC-13, 125 V
0.8 A
Rated operation current Ie at DC-13, 230 V
0.3 A
Switching function
Slow-action switch
Switching function latching
No
Output electronic
No
Forced opening
Yes
Number of safety auxiliary contacts
1
Number of contacts as normally closed contact
1
Number of contacts as normally open contact
1
Number of contacts as change-over contact
0
Type of interface
None
Type of interface for safety communication
None
Construction type housing
Cuboid
Housing material
Plastic
Coating housing
Other
Type of control element
Plunger
Alignment of the control element
Roller cam straight
Type of electric connection
Cable entry metrical
With status indication
No
Suitable for safety functions
Yes
Explosion safety category for gas
None
Explosion safety category for dust
None
Ambient temperature during operating
-25 - 70 °C
Degree of protection (IP)
IP66/IP67
Degree of protection (NEMA)