General specifications
Product name
Eaton Distribution parts
Part no.
Z-FW-LPD
EAN
4015082652449
Product Length/Depth
80 millimetre
Product height
77.3 millimetre
Product width
88.4 millimetre
Product weight
0.247 kilogram
Compliances
RoHS conform
Product Tradename
None
Product Type
Distribution parts
Product Sub Type
None
Public Consumption
Yes
Product Family Description
ES-PMCC-PDC-Eaton Distribution parts
Globally Marketable
Yes
Product Specification Details
Accessory/spare part type
Restarting device
Additional equipment required
Monitoring unit with automatic reclosing
Ambient operating temperature - max
40 °C
Ambient operating temperature - min
-25 °C
Application
Switchgear for industrial and advanced commercial applications
Assembly width
4
Degree of protection
IP40
Device fitting
Universal
Enclosure width
80 mm
Equipment heat dissipation, current-dependent
0 W
Frame
Standard front dimension: 45 mm
Function selector
Automatic 5 x, OFF/RESET
Functions
Automatic restart
With auto test for earth leakage function
Remote drive
Heat dissipation capacity
0 W
Heat dissipation per pole, current-dependent
0 W
Mounting width
70 mm
Number of contacts (change-over contacts)
0
Number of contacts (normally closed contacts)
0
Number of contacts (normally open contacts)
0
Number of poles at main contact unit - max
0
Number of switches (fault signal)
0
Rated operational current for specified heat dissipation (In)
0 A
Rated operational voltage (Ue) - max
48 V
Rated switch current
0 A
Relay output for alarm
5 A
Special features
Z-FW… (Test module (0.5 space unit) for remote testing of residual current devices)
Static heat dissipation, non-current-dependent
0.8 W
Suitable for current of main contact unit - max
0 A
Terminal capacity (cable)
2.5 mm² (1x)
1.5 mm² (2x)
Terminal capacity (solid wire)
1 mm² - 2.5 mm²
1.5 mm² (2x)
Terminal protection
Protection against electric shock to BGV A3, ÖVE-EN 6
Terminal type
Lift terminals
Type
Accessory
Accessory for miniature circuit breaker
Accessory for residual current circuit breaker
Used with
Restarting device
Accessory for residual current circuit breaker
Accessory
Accessory for miniature circuit breaker
Voltage rating at DC
24 V DC - 48 V DC
Voltage type
DC

Technical data ETIM 9.0

Devices for distribution board-/surface mounting (EG000062) / Auxiliary device for distribution board devices (EC001286)
Electric engineering, automation, process control engineering / Electrical installation, device / Breaker switch component / Auxiliary contact unit for distribution board (ecl@ss13-27-14-35-02 [AKE327018])
Device fitting
Universal
Function
Remote drive
Width in number of modular spacings
4
Number of contacts as normally open contact
0
Number of contacts as normally closed contact
0
Number of contacts as change-over contact
0
Number of fault-signal switches
0
Rated switch current
0 A
Rated voltage
48 V
Voltage type
DC
With auto test for earth leakage function
Yes
Suitable for max. number of poles main contact unit (total)
0
Suitable for max. current main contact unit
0 A