General specifications
Product name
Eaton Moeller series NZM connection type
Part no.
NZM3-XKS185
EAN
4015082600402
Product Length/Depth
78 millimetre
Product height
26.5 millimetre
Product width
31 millimetre
Product weight
0.104 kilogram
Compliances
IEC
RoHS conform
Product Tradename
NZM
Product Type
Accessories
Product Sub Type
Connection type
Delivery program
Type
Accessory Cable lugs Terminal
Number of poles
Three-pole/Four-pole
Special features
Not UL/CSA approved. Narrow tubular cable lugs for switchgear connections. When using without cover NZM3(-4)-XKSA, the cable lug must be insulated.
Frame
NZM3/4
Used with
NZM3(-4), PN3(-4), N3(-4)
NZM4(-4), N(-4)
Technical Data - Mechanical
Nominal cross section
185 mm²
Surface protection
Tinned
Number of mounting holes
1
Connecting angle
180° (horizontal)
Bolt dimension
0 mm
Identification color
None
Special features
Not UL/CSA approved. Narrow tubular cable lugs for switchgear connections. When using without cover NZM3(-4)-XKSA, the cable lug must be insulated.
Technical Data - Mechanical - Terminals
Terminal capacity (stranded cable)
185 mm²
Design verification as per IEC/EN 61439
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Additional information
Code digit
0

Technical data ETIM 9.0

Installation, isolation and connection material (EG000047) / Crimp cable lug for copper conductors (EC001050)
Electric engineering, automation, process control engineering / Electrical insulation and connecting material / Lug, conductor sleeve, connector / Crimp cable lug for copper conductors (ecl@ss13-27-40-02-03 [AKN512018])
Bolt dimension (metric)
0
Connecting angle
180° (horizontal)
Number of mounting holes
1
Code digit
0
Nominal cross section
185 mm²
Surface protection
Tinned
Identification colour
None