General specifications
Product name
Eaton Moeller series NZM connection type
Part no.
NZM3-XKS
EAN
4015082600396
Product Length/Depth
120.5 millimetre
Product height
459 millimetre
Product width
140 millimetre
Product weight
0.14 kilogram
Compliances
IEC
UL/CSA
RoHS conform
Certifications
UL (Category Control Number DIHS)
CSA-C22.2 No. 5-09
CE marking
CSA (Class No. 1437-01)
UL listed
UL (File No. E31593)
CSA (File No. 22086)
UL489
CSA certified
IEC60947
Product Tradename
NZM
Product Type
Accessories
Product Sub Type
Connection type
Delivery program
Type
Accessory Screw connection Terminal
Number of poles
Three-pole
Amperage Rating
630 A
Frame
NZM3
Suitable for
Copper cable lugs
Three-pole
Aluminum cable lug
Used with
NZM3, PN3, N(S)3
Technical Data - Mechanical - Terminals
Terminal capacity (stranded cable)
16 mm² - 300 mm² (1x)
4 - 350 AWG/kcmil (1x)
16 mm² - 240 mm² (2x)
350 AWG/kcmil (2x)
Terminal capacity (copper busbar)
30 mm x 10 mm + 30 mm x 5 mm
Terminal capacity (copper strip)
10 segments of 32 mm x 1 mm + 5 segments of 32 mm x 1 mm
Design verification as per IEC/EN 61439
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Additional information
Model
Other

Technical data ETIM 8.0

Low-voltage industrial components (EG000017) / Wiring set for power circuit breaker (EC002050)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Wiring set for circuit breaker (ecl@ss10.0.1-27-37-04-24 [ACN957011])
Suitable for number of poles
3
Model
Other