248442 Z-LHASA/230
Shunt release, up to 125A, 110-415V, 1.5HP
Shunt release, for MCB up to 125A, voltage range 110-415V AC, max. current consumption at switch-on time Un 2 A, frequency 50/60hz, can be retrofitted, standard front dimension 45 mm, mounting width 1.5 space units (27mm), top-hat rail mounting, terminal cross-section 1–25 mm²
General specifications
Product name
Eaton Distribution parts
Part no.
Z-LHASA/230
EAN
4015082484422
Product Length/Depth
80 millimetre
Product height
75 millimetre
Product width
39.1 millimetre
Product weight
0.158 kilogram
Compliances
RoHS conform
Certifications
EN45545-2
IEC 61373
IEC 61373
Product Tradename
None
Product Type
Distribution parts
Product Sub Type
None
Public Consumption
Yes
PDH Status
Active
Product Family Description
ES-PMCC-PDC-Eaton Distribution parts
Globally Marketable
Yes
Product Specification Details
Accessory/spare part type
Shunt release
Additional equipment required
Shunt release (for power circuit breaker)
Ambient operating temperature - max
40 °C
Ambient operating temperature - min
-5 °C
Application
Switchgear for industrial and advanced commercial applications
Assembly width
1.5
Device fitting
Miniature circuit breaker (MCB)
EL number
1609566
Functions
Shunt release (for power circuit breaker)
Mounting method
For fitting on left to: AZ
Number of contacts (change-over contacts)
0
Number of contacts (normally closed contacts)
1
Number of contacts (normally open contacts)
1
Number of poles at main contact unit - max
1
Number of switches (fault signal)
0
Rated operational voltage (Ue) - max
230 V
Rated switch current
2 A
Suitable for current of main contact unit - max
2 A
Type
Accessory for miniature circuit breaker
Accessory
Accessory
Used with
Shunt releases
Voltage type
AC
Technical data ETIM 9.0
Devices for distribution board-/surface mounting (EG000062) / Equipo adicional para dispositivos montados en carril DIN (EC001286)
Tecnología electrónica, de automatización y de mando de procesos / Instalación eléctricas, equipo / Componente de disyuntor de protección / Contacto auxiliar, contacto de señal (ecl@ss13-27-14-35-02 [AKE327018])
Device fitting
Miniature circuit breaker (MCB)
Function
Shunt release (for power circuit breaker)
Width in number of modular spacings
1.5
Number of contacts as normally open contact
1
Number of contacts as normally closed contact
1
Number of contacts as change-over contact
0
Number of fault-signal switches
0
Rated switch current
2 A
Rated voltage
230 V
Voltage type
AC
With auto test for earth leakage function
No
Suitable for max. number of poles main contact unit (total)
1
Suitable for max. current main contact unit
2 A
-
(Web)
-
Asset
-
Asset
-
Asset
-
Line drawing
-
Line drawing
-
Eaton EMEA Download-Center - download data for this item
-
Eaton EMEA Download-Center