199351 M22-PVLT30/FK11/RG/FIY1

Delivery program

Product range
RMQ-Titan
Basic function
Housing
Controlled stop pushbuttons/emergency-stop buttons
Mounting hole diameter [⌀]
22.5 mm
Single unit/Complete unit
Complete unit
Design
Mushroom-shaped
Diameter [⌀]
30 mm
Illumination
Illuminated with LED element
Turn-to-release function
Connection type
Cage Clamp
Description
Tamper-proof according to ISO 13850/EN 418
Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/Minden, Germany
Turn to release
Number of locations
1 Qty.
Colour
Mushroom head
Red
1160SPC-80
Base
yellow
Enclosure covers
Yellow
RAL Value
RAL 3000
LED
red/green
Degree of Protection
IP65, IP66, IP69
Connection to SmartWire-DT
no
Contacts
N/C = Normally closed
1 NC
N/O = Normally open
1 N/O
Notes
= safety function, by positive opening to IEC/EN 60947-5-1
Actuator travel and actuation force as per DIN EN 60947-5-1, K.5.4.1
[mm]
5.5
Maximum travel [mm]
5.8
Contact sequence
116S035
Positive opening (ZW)
yes

Technical data

General
Standards
IEC/EN 60947
VDE 0660
certificate
CE, EAC UL, CSA, CCC
Lifespan, mechanical [Operations]
60000
Operating frequency [Operations/h]
≦ 600
Actuating force
≦ 50 n
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Degree of Protection
IP65, IP66, IP69
Ambient temperatureOpen
-25 - +70 °C
Mounting position
As required
Mechanical shock resistance
50
Shock duration 11 ms
Sinusoidal
according to IEC 60068-2-27 g
Terminal capacitiesSolid
2 x 1 (0.2 - 1.5)
2 x 1 (075 - 1.5) Can be plugged without tools mm2
Terminal capacitiesFlexible with ferrule
2 x 1 (0.25 - 1)
Use WAGO Variocrimp 4 crimping tool; please enquire for others mm2
Terminal capacitiesSolid or stranded
2 x 1 (24 - 16) AWG
shipping classification
DNV
GL
LR
0000SPC-1830000SPC-1800000SPC-179
Contacts
Rated conditional short-circuit current [Iq]
1 kA
Overvoltage category/pollution degree
III/3
Max. short-circuit protective deviceFuseless
FAZ-B4 Type
Max. short-circuit protective deviceFuse [gG/gL]
4 A

Design verification as per IEC/EN 61439

Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+70 °C

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Control circuit devices combination in enclosure (EC000225)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Command and alarm device / Command and alarm device combination in housing (ecl@ss10.0.1-27-37-12-16 [AKF034014])
Number of command positions
Number of push buttons
Number of indicator lights
Number of key switches
Number of selector switches
Number of mushroom-shaped push-buttons
Suitable for emergency stop
Rated control supply voltage Us at AC 50HZ
V
Rated control supply voltage Us at AC 60HZ
V
Rated control supply voltage Us at DC
V
Colour housing cover
Material housing
Number of contacts as normally open contact
Number of contacts as normally closed contact
Number of contacts as change-over contact
Degree of protection (IP)
Degree of protection (NEMA)

Approvals

Product Standards
IEC/EN 60947-5; UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94-91; CE marking
UL File No.
E29184
UL Category Control No.
NKCR
CSA File No.
012528
CSA Class No.
3211-03
North America Certification
UL listed, CSA certified

Dimensions

1160DIM-218