197669 XV-363-12-C02-A00-1B
Single touch display, 12-inch display, 24 VDC, 800 x 600 px, 2x Ethernet, 1x RS232, 1x RS485, 1x CAN, 1x DP, PLC function can be fitted by user
12.1" infrared touch panel in 4:3 format; built-in unit; resolution 800 x 600 pixels; Can be used in portrait or landscape mode; PLC function can be retrofitted with article no. 181585 LIC-PLC-A; laminated safety glass in aluminum front; robust and easy to clean; metal housing; SD card slot; operating system: Windows Embedded Compact 7 Pro; two independent Ethernet interfaces for safe isolation of the higher-level IT communication and machine network; other interfaces: CAN, Profibus-DP, RS232, RS485; USB host 2.0 , USB device; can be configured with Galileo and XSOFT-CODESYS-2/3; integrated runtime license for visualization; degree of protection at front: IP65
General specifications
Product name
Eaton XV-363 Touch panel
Part no.
XV-363-12-C02-A00-1B
EAN
7640130099401
Product Length/Depth
361 millimetre
Product height
100 millimetre
Product width
279 millimetre
Product weight
2.2 kilogram
Certifications
EAC
EN 50178
IEC/EN 61131-2
EN 50178
IEC/EN 61131-2
Product Tradename
XV-363
Product Type
Touch panel
Product Sub Type
None
Globally Marketable
Yes
Current consumption at 24 V DC
Features & Functions
Features
USB device
USB Host
Ethernet interface
PLC function can be fitted by user
CAN
Fanless CPU and system cooling, natural convection-based passive cooling
Portrait format
RS232
Slot for SD card
RS485
USB Host
Ethernet interface
PLC function can be fitted by user
CAN
Fanless CPU and system cooling, natural convection-based passive cooling
Portrait format
RS232
Slot for SD card
RS485
Fitted with:
Recipes
1 x USB device (built-in interface)
1 x RS485 (built-in interface)
Message system (incl. buffer and confirmation)
1 x CAN (built-in interfaces)
MPI interface
Numeric keyboard
Color display
Message indication
1 x PROFIBUS (built-in interface)
1 x RS232 (built-in interface)
1 x USB host 2.0 (built-in interface)
2 x Ethernet 10/100 Mbps (built-in interface)
Alpha numeric keyboard
1 x USB device (built-in interface)
1 x RS485 (built-in interface)
Message system (incl. buffer and confirmation)
1 x CAN (built-in interfaces)
MPI interface
Numeric keyboard
Color display
Message indication
1 x PROFIBUS (built-in interface)
1 x RS232 (built-in interface)
1 x USB host 2.0 (built-in interface)
2 x Ethernet 10/100 Mbps (built-in interface)
Alpha numeric keyboard
Functions
Additional software components, loadable
Process default value (input) possible
Process value representation (output) possible
Process default value (input) possible
Process value representation (output) possible
General information
Battery runtime
Back-up of real-time clock: BR 2330, non-replaceable (soldered)
Degree of protection
IP20, rear (according to EN 60529-1)
Degree of protection (front side)
IP65
NEMA 12
NEMA 12
Fuse type
Built-in fuse (not accessible)
Model
Metal enclosure and glass front in aluminum frame
Mounting method
Flush mounting - Clearance: Width x Height x Depth ≥ 30 mm (1.18")
Flush mounting
Flush mounting
Product category
XV-300
RoHs conformity
Yes
Software
XSOFT-CODESYS, Visualisation software, Engineering
XSOFT-CODESYS-2, PLC-Programming software, Engineering
GALILEO, Visualisation software, Engineering
XSOFT-CODESYS-3, PLC-Programming software, Engineering
XSOFT-CODESYS-2, PLC-Programming software, Engineering
GALILEO, Visualisation software, Engineering
XSOFT-CODESYS-3, PLC-Programming software, Engineering
Type
HMI (SPS function, retrofittable)
Voltage type
DC
Ambient conditions, mechanical
Shock resistance
15 g, 11 ms, Mechanical
Climatic environmental conditions
Air pressure
795 - 1080 hPa (operation)
Ambient operating temperature - min
0 °C
Ambient operating temperature - max
50 °C
Ambient storage temperature - min
-20 °C
Ambient storage temperature - max
60 °C
Climatic proofing
Dry heat to IEC 60068-2-2
Cold to EN 60068-2-1
Damp heat, constant, to IEC 60068-2-3
Cold to EN 60068-2-1
Damp heat, constant, to IEC 60068-2-3
Environmental conditions
Condensation: Non-condensing
Operating temperature - min
0 °C
Operating temperature - max
50 °C
Relative humidity
10 - 95 % (non-condensing)
Electro magnetic compatibility
Interference immunity
According to EN 61000-6-2
Radio interference class
Class A (EN 55011)
Voltage dips
5 ms from undervoltage (19.2 V DC)
≤ 10 ms from rated voltage (24 V DC)
≤ 10 ms from rated voltage (24 V DC)
Electrical rating
Permissible voltage
19.2 - 30 V DC, absolute with ripple
35 V DC (for a duration of < 100 ms)
18 - 31.2 V DC, battery powered (rated operating voltage -25 %/+30 %)
19.2 - 30 V DC, effective (rated operating voltage -20 %/+25 %)
35 V DC (for a duration of < 100 ms)
18 - 31.2 V DC, battery powered (rated operating voltage -25 %/+30 %)
19.2 - 30 V DC, effective (rated operating voltage -20 %/+25 %)
Power consumption
Max 20.5 W
Rated operational voltage
24 V DC (power-supply - safety extra low voltage)
Supply voltage at AC, 50 Hz - min
0
Supply voltage at AC, 50 Hz - max
0
Supply voltage at DC - min
19.2
Supply voltage at DC - max
30
Communication
Communication interface
PROFIBUS-DP, not galvanically isolated, 9 pole SUB-D socket, UNC
Interfaces
USB 2.0 host (not galvanically isolated)
CAN (not galvanically isolated, 9-pin SUB-D plug, UNC)
10/100 Mbps Ethernet connection
RS232 (not galvanically isolated, 9-pin SUB-D plug, UNC)
RS485 (not galvanically isolated, 9-pin SUB-D plug, UNC)
USB 2.0 device (not galvanically isolated)
CAN (not galvanically isolated, 9-pin SUB-D plug, UNC)
10/100 Mbps Ethernet connection
RS232 (not galvanically isolated, 9-pin SUB-D plug, UNC)
RS485 (not galvanically isolated, 9-pin SUB-D plug, UNC)
USB 2.0 device (not galvanically isolated)
Number of slots
1 (for SD-Card)
Protocol
EtherNet/IP
MODBUS
Other bus systems
TCP/IP
CAN
PROFIBUS
MODBUS
Other bus systems
TCP/IP
CAN
PROFIBUS
Display
Display contrast ratio
500:1
Display size
4:3
246 x 185 mm
246 x 185 mm
Display type
Laminated safety glass, anti-glare in aluminum frame
TFT
Color display, TFT
TFT
Color display, TFT
Number of colors of the display
65536
Resolution
800 x 600 px
Screen size (diagonal)
12.1 in
Touch technology
Laminated safety glass, non-reflective, Infrared touch protective screen
Infrared touch
Single-touch display
Infrared touch
Single-touch display
System
Backup time
10 years, typ. (time at zero voltage)
Memory
SD card, Type: SDSC, SDHC (external memory)
NVRAM: 128kByte Retain
DRAM: 512 MByte RAM
Flash: 1 GByte SLC
NVRAM: 128kByte Retain
DRAM: 512 MByte RAM
Flash: 1 GByte SLC
Memory capacity
512,000 kByte
Operating system
Windows Embedded Compact 7 Pro
Processor
ARM Cortex-A9 800 MHz
Design verification
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Static heat dissipation, non-current-dependent Pvs
20.5 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Please enquire
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Technical data ETIM 8.0
Programmable logic controllers PLC (EG000024) / Graphic panel (EC001412)
Electric engineering, automation, process control engineering / Display and control component / Panel (HMI) / Graphic panel (HMI) (ecl@ss10.0.1-27-33-02-01 [AFX016003])
Supply voltage AC 50 Hz
0 - 0 V
Supply voltage AC 60 Hz
0 - 0 V
Supply voltage DC
19.2 - 30 V
Voltage type of supply voltage
DC
Number of HW-interfaces industrial Ethernet
2
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
1
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
2
Number of HW-interfaces parallel
0
Number of HW-interfaces Wireless
0
Number of HW-interfaces other
3
With SW interfaces
No
Supporting protocol for TCP/IP
Yes
Supporting protocol for PROFIBUS
Yes
Supporting protocol for CAN
Yes
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for Modbus
Yes
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
Yes
Radio standard Bluetooth
No
Radio standard Wi-Fi 802.11
No
Radio standard GPRS
No
Radio standard GSM
No
Radio standard UMTS
No
IO link master
No
Type of display
TFT
With colour display
Yes
Number of colours of the display
65,536
Number of grey-scales/blue-scales of display
0
Screen diagonal
12.1 inch
Number of pixels, horizontal
800
Number of pixels, vertical
600
Useful project memory/user memory
512,000 kByte
With numeric keyboard
Yes
With alpha numeric keyboard
Yes
Number of function buttons, programmable
0
Number of buttons with LED
0
Number of system buttons
1
Touch technology
Infrared touch
With message indication
Yes
With message system (incl. buffer and confirmation)
Yes
Process value representation (output) possible
Yes
Process default value (input) possible
Yes
With recipes
Yes
Number of password levels
200
With printer output
No
Number of online languages
100
Additional software components, loadable
Yes
Degree of protection (IP), front side
IP65
Degree of protection (NEMA), front side
12
Operating temperature
0 - 50 °C
Rail mounting possible
No
Wall mounting/direct mounting
No
Suitable for safety functions
No
Width of the front
361.2 mm
Height of the front
279.2 mm
Built-in depth
63 mm
-
(Web)
-
Asset
-
Asset
-
Asset
-
Asset
-
Eaton EMEA Download-Center - download data for this item
-
Eaton EMEA Download-Center