General specifications
Product name
Eaton Distribution parts
Part no.
VLCE22-3P
EAN
4015081929214
Product Length/Depth
75.8 millimetre
Product height
120.4 millimetre
Product width
106.8 millimetre
Product weight
0.476 kilogram
Compliances
RoHS conform
Product Tradename
None
Product Type
Distribution parts
Product Sub Type
None
Public Consumption
Yes
Product Family Description
ES-PMCC-PDC-Eaton Distribution parts
Globally Marketable
Yes
Product Specification Details
Actuator position
Front side
Actuator type
Rocker lever
Ambient operating temperature - max
55 °C
Ambient operating temperature - min
-25 °C
Cable entry type
Other
Conditioned rated short-circuit current Iq
100 kA
Creepage resistance
CTI 400
Degree of protection
IP20
Degree of protection (front side)
IP20
Electrical connection type of main circuit
Screw connection
Enclosure width
121 mm
Features
Version as safety switch
Frame
Standard front dimension: 45 mm
Frequency rating
50 Hz
Functions
Fuse switch-disconnector VLC…, empty
Mounting width
36 mm per pole
Number of poles
Three-pole
Permitted heat loss from fuse links - max
gG: 9.5 W, aM: 7 W
Pollution degree
1
Power rating at AC-23, 400 V
0 kW
Rated conditional short-circuit current (Iq)
100 kA
Rated conditional short-circuit rating
100 kA
Rated impulse withstand voltage (Uimp)
8 kV
Rated operating voltage (Ue) at AC - max
690 V
Rated operation current (Ie)
100 A
Rated operation power at AC-23, 400 V
0 kW
Rated short-time withstand current (Icw)
0.6 kA
Rated uninterrupted current (Iu)
50 A
Size
22 mm x 58 mm
Special features
For cylindrical fuses
Up to 100 A
Without flashing function
Suitable for
Ground mounting
Suitable for fuses
22x58 mm
Terminal capacity (solid cable)
2.5 mm² - 35 mm² (1x)
Terminals
Lift terminals
Type
Fuse material
Utilization category
AC-21 B
Voltage rating
690 V AC

Technical data ETIM 8.0

Low-voltage industrial components (EG000017) / Fuse switch disconnector (EC001040)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Fuse switch disconnector (ecl@ss10.0.1-27-37-14-01 [AKF058013])
Version as main switch
No
Version as safety switch
Yes
Max. rated operation voltage Ue AC
690 V
Rated permanent current Iu
50 A
Rated operation power at AC-23, 400 V
0 kW
Conditioned rated short-circuit current Iq
100 kA
Rated short-time withstand current lcw
0.6 kA
Suitable for fuses
22x58 mm
Number of poles
3
With error protection
No
Type of electrical connection of main circuit
Screw connection
Cable entry
Other
Equipped with connectors
No
Suitable for floor mounting
Yes
Suitable for front mounting
No
Suitable for busbar mounting
No
Type of control element
Rocker lever
Position control element
Front side
Motor drive optional
No
Motor drive integrated
No
Version as emergency stop installation
No
Degree of protection (IP), front side
IP20