Delivery program

Product range
RMQ compact solution
Basic function
Controlled stop pushbuttons/emergency-stop buttons
Mounting hole diameter [⌀]
22.5 mm
Single unit/Complete unit
Complete unit
Design
Mushroom-shaped
Diameter [⌀]
38 mm
Illumination
Non-illuminated
Turn-to-release function
Connection type
Cable (black) with M12A plug, 5 pole
Cable Length
0.2 m
Description
Tamper-proof according to ISO 13850, EN 418
Colour
Mushroom head
Red
1160SPC-79
Base
yellow
Degree of Protection
IP66, IP67, IP69 (front)
IP65 (on rear)
Connection to SmartWire-DT
no
Contacts
N/C = Normally closed
2 NC
Notes
= safety function, by positive opening to IEC/EN 60947-5-1
Actuator travel and actuation force as per DIN EN 60947-5-1, K.5.4.1
[mm]
4.65
Maximum travel [mm]
5.7
Minimum force for positive opening [ N]
30
Contact sequence
1160SWI-75
Contact travel■ = Contact closed□ = Contact open
Contact diagram
1160DIA-14
Positive opening (ZW)
yes

Technical data

General
Standards
IEC/EN 60947-5-5
VDE 0660
Certifications
CE, UL, CSA
Lifespan, mechanical [Operations]
> 0.05 x 106
Operating frequency [Operations/h]
≦ 300
Actuating force
≦ 50 n
Plug tightening torque
1 N/m
Tightening torque Threaded ring
2 Nm
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Degree of Protection
IP66, IP67, IP69 (front)
IP65 (on rear)
Ambient temperatureOpen
-30 - +70 °C
Ambient temperatureStorage
- 30 - + 80 °C
Mounting position
As required
Mechanical shock resistance, shock duration 11 ms
> 30 g
Contacts
Rated impulse withstand voltage [Uimp]
800 V AC
Rated insulation voltage [Ui ]
30 V
Overvoltage category/pollution degree
III/3
Control circuit reliabilityAt 17 V DC/7 mA [HF ]
N/C contact: statistically determined 1 failure per 0.9 × 106 Operations
Max. short-circuit protective deviceFuse [gG/gL]
4 A
Rated conditional short-circuit current [Iq]
1 kA
Switching capacity
Rated operational current [Ie ]AC-1524 V [Ie ]
4 A
Rated operational current [Ie ]DC-13 24 V [Ie ]
3 A
Cable characteristics
Design
M12A
Cable Length
0.2 m
Material characteristic
PUR
Diameter [⌀]
4.7 mm

Design verification as per IEC/EN 61439

Operating ambient temperature min.
-30 °C
Operating ambient temperature max.
+70 °C

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Emergency stop complete (EC002034)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Command and alarm device / EMERGENCY-STOP pushbutton, complete device (ecl@ss10.0.1-27-37-12-44 [ACN986011])
Unlocking method
Turn-release
Number of contacts as normally closed contact
2
Number of contacts as normally open contact
0
Degree of protection (IP)
Other
Mounting method
Built-in
With lighting
No
Hole diameter
22.5 mm
Connection type auxiliary circuit
Other
Diameter cap
38 mm

Approvals

Product Standards
IEC/EN 60947-5-1; UL 508; CAN/CSA-C22.2 No. 14-10 and No. 94-M91 and No. 94.2-07; CE marking
UL File No.
E340491
CSA File No.
165628
CSA Class No.
321103
North America Certification
UL listed, CSA certified
Degree of Protection
1,3R,4X,12,13

Dimensions

1160DIM-141