183314 DILDC300/22(RDS250)

Delivery program

Product range
Contactors
Application
DC contactor
Subrange
Comfort devices greater than 170 A
Instructions
DILDC contactors feature an electronic arc suppression system. Because of this, it is important not to exceed any technical data limits in general – especially the making and breaking capacity limits. Opening the device will immediately void the warranty.
integrated suppressor circuit in actuating electronics
Connection technique
Screw connection
Rated operational current, open
DC-1Notes
Ie at 60 °C
DC-11000 V [Ie]
300 A
Can be combined with auxiliary contact
DILM820-XHI…
Actuating voltage
RDS 250: 110 - 250 V 40 - 60 Hz/110 - 350 V DC
Voltage AC/DC
AC and DC operation
Contacts
N/O = Normally open
2 N/O
N/C = Normally closed
2 NC
Auxiliary contacts
possible variants at auxiliary contact module fitting options
on the side: 2 x DILM820-XHI11(V)-SI; 2 x DILM820-XHI11-SA

Technical data

General
Standards
EN60947-4-1, EN60947-5-1
Lifespan, mechanicalAC operated [Operations]
1 x 106
Lifespan, mechanicalDC operated [Operations]
1 x 106
Operating frequency, mechanicalAC operated [Operations/h]
1000
Operating frequency, mechanicalDC operated [Operations/h]
1000
Maximum operating frequencyelectrical (Contactors without overload relay) [Operations/h]
100
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperatureOpen
-40 - +70 °C
Ambient temperatureEnclosed
- 40 - + 40 °C
Ambient temperatureStorage
- 40 - + 80 °C
Mechanical shock resistance (IEC/EN 60068-2-27)Half-sinusoidal shock, 10 msMain contactsN/O contact
10 g
Mechanical shock resistance (IEC/EN 60068-2-27)Half-sinusoidal shock, 10 msAuxiliary contactsN/O contact
10 g
Mechanical shock resistance (IEC/EN 60068-2-27)Half-sinusoidal shock, 10 msAuxiliary contactsN/C contact
8 g
Degree of Protection
IP00
Protection against direct contact when actuated from front (EN 50274)
Covers on main terminals safeguarded against accidental contact with fingers or back of hand
Altitude
Max. 2000 m
WeightWeight
7.5 kg
Terminal capacity main cableFlexible with cable lug
50 - 240 mm2
Terminal capacity main cableStranded with cable lug
50 - 240 mm2
Terminal capacity main cableSolid or stranded
1/0 - 500 MCM AWG
Terminal capacity main cableBusbar [Width]
40 mm
Main cable connection screw/bolt
M10
Tightening torque
24 Nm
Terminal capacity control circuit cablesSolid
1 x (0.75 - 2.5)
2 x (0.75 - 2.5) mm2
Terminal capacity control circuit cablesFlexible with ferrule
1 x (0.75 - 2.5)
2 x (0.75 - 2.5) mm2
Terminal capacity control circuit cablesSolid or stranded
2 x (18 - 12) AWG
Control circuit cable connection screw/bolt
M3.5
Tightening torque
1.2 Nm
ToolMain cableWidth across flats
16 mm
ToolControl circuit cablesPozidriv screwdriver
2 Size
ToolControl circuit cablesStandard screwdriver
0.8 x 5.5
1 x 6 mm
Main conducting paths
Rated impulse withstand voltage [Uimp]
8000 V
Overvoltage category/pollution degree
III/3
Rated insulation voltage [Ui]
1000 V DC
Rated operational voltage [Ue]
1000 V DC
Safe isolation to EN 61140Between control inputs and main contacts
1000 V
Safe isolation to EN 61140Between auxiliary contacts and main contacts
1000 V
Safe isolation to EN 61140between the contacts
1000 V
Making capacity
450 A
Breaking capacity 220 V 230 V
450 A
Breaking capacity 380 V 400 V
450 A
Breaking capacity 500 V
450 A
Breaking capacity 660 V 690 V
450 A
Breaking capacity 1000 V
450 A
Short-circuit ratingShort-circuit protection maximum fuseType “2” coordination 400 V DC [gR 1000 VDC]
450 (max. short-circuit current 6 kA) A
Short-circuit ratingShort-circuit protection maximum fuseType “2” coordination 690 V DC [gR 1000 VDC]
450 (max. short-circuit current 6 kA) A
Short-circuit ratingShort-circuit protection maximum fuseType “2” coordination 1000 V DC [gR 1000 VDC]
450 (max. short-circuit current 6 kA) A
Short-circuit ratingShort-circuit protection maximum fuseType “1” coordination 400 V DC [gR 1000 VDC]
450 (max. short-circuit current 30 kA) A
Short-circuit ratingShort-circuit protection maximum fuseType “1” coordination 690 V DC [gR 1000 VDC]
450 (max. short-circuit current 30 kA) A
Short-circuit ratingShort-circuit protection maximum fuseType “1” coordination 1000 V DC [gR 1000 VDC]
450 (max. short-circuit current 30 kA) A
DC
Rated operational current, openDC-1Notes
Ie at 60 °C
Rated operational current, openDC-11000 V [Ie]
300 A
Current heat loss
1 pole, at Ith
18 W
Magnet systems
Voltage toleranceUS
110 - 250 V 40-60 Hz
110 - 350 V DC
Voltage toleranceAC operated [Pick-up]
0.7 x US min - 1.15 x US max
Voltage toleranceDC operated [Pick-up]
0.7 x US min - 1.15 x US max
Voltage toleranceAC operated [Drop-out]
0.2 x US max - 0.6 x US min
Voltage toleranceDC operated [Drop-out]
0.2 x US max - 0.6 x US min
Voltage toleranceActuation directly from PLCUC
24 V DC
Voltage toleranceActuation directly from PLCUC min - max
15 - 31,2 V DC
Power consumption of the coil in a cold state and 1.0 x USNote on power consumption
Control transformer with uk ≦ 6%
Power consumption of the coil in a cold state and 1.0 x USPull-in power [Pick-up]
600 VA
Power consumption of the coil in a cold state and 1.0 x USPull-in power [Pick-up]
550 W
Power consumption of the coil in a cold state and 1.0 x USSealing power [Sealing]
18 VA
Power consumption of the coil in a cold state and 1.0 x USSealing power [Sealing]
9.5 W
Duty factor
100 % DF
Changeover time at 100 % US (recommended value)Main contactsClosing delay
80 ms
Changeover time at 100 % US (recommended value)Main contactsOpening delay
40 ms
PLC signal level (A3 - A4) to IEC/EN 61131-2 (type 2)High
15 V
PLC signal level (A3 - A4) to IEC/EN 61131-2 (type 2)Low
5 V
Electromagnetic compatibility (EMC)
Electromagnetic compatibility
This product is designed for operation in industrial environments (environment A). Its use in residential environments (environment B) may cause radio-frequency interference, requiring additional noise suppression measures.
Rating data for approved types
Switching capacityMaximum motor ratingSingle-phaseGeneral use
300 A
Auxiliary contactsPilot DutyAC operated
A600
Auxiliary contactsPilot DutyDC operated
P300
Auxiliary contactsGeneral UseAC
600 V
Auxiliary contactsGeneral UseAC
15 A
Auxiliary contactsGeneral UseDC
250 V
Auxiliary contactsGeneral UseDC
1 A

Design verification as per IEC/EN 61439

Datos técnicos para la verificación del diseño
Intensidad asignada de empleo para disipación térmica específica [In]
300 A
Disipación térmica por polo, en función de la intensidad [Pvid]
18 W
Disipación térmica del equipo, en función de la intensidad [Pvid]
0 W
Disipación térmica estática, en función de la intensidad [Pvs]
9 W
Capacidad de disipación térmica [Pdiss]
0 W
Temperatura ambiente mínima de funcionamiento
-40 °C
Temperatura ambiente máxima de funcionamiento
+70 °C
Verificación de diseño IEC / EN 61439
10.2 Resistencia de materiales y piezas10.2.2 Resistencia a la corrosión
Cumple con los requisitos de la norma del producto.
10.2 Resistencia de materiales y piezas10.2.3.1 Verificación de la estabilidad térmica de los armarios
Cumple con los requisitos de la norma del producto.
10.2 Resistencia de materiales y piezas10.2.3.2 Verificación de la resistencia de los materiales aislantes en condiciones de calor normales
Cumple con los requisitos de la norma del producto.
10.2 Resistencia de materiales y piezas10.2.3.3. Verificación de la resistencia de los materiales aislantes al calor excesivo y al fuego debido a los efectos eléctricos internos
Cumple con los requisitos de la norma del producto.
10.2 Resistencia de materiales y piezas10.2.4 Resistencia a radiación ultravioleta (UV)
Cumple con los requisitos de la norma del producto.
10.2 Resistencia de materiales y piezas10.2.5 Elevación
No se aplica, ya que todo el equipo de conmutación debe ser evaluado.
10.2 Resistencia de materiales y piezas10.2.6 Impacto mecánico
No se aplica, ya que todo el equipo de conmutación debe ser evaluado.
10.2 Resistencia de materiales y piezas10.2.7 Inscripciones
Cumple con los requisitos de la norma del producto.
10.3 Grado de protección de montajes
No se aplica, ya que todo el equipo de conmutación debe ser evaluado.
10.4 Distancias de separación y fuga
Cumple con los requisitos de la norma del producto.
10.5 Protección contra descargas eléctricas
No se aplica, ya que todo el equipo de conmutación debe ser evaluado.
10.6 Incorporación de dispositivos y componentes de conmutación
No se aplica, ya que todo el equipo de conmutación debe ser evaluado.
10.7 Conexiones y circuitos eléctricos internos
Es responsabilidad del cuadrista.
10.8 Conexiones de conductores externos
Es responsabilidad del cuadrista.
10.9 Propiedades de aislamiento10.9.2 Resistencia eléctrica de frecuencia de alimentación
Es responsabilidad del cuadrista.
10.9 Propiedades de aislamiento10.9.3 Tensión de impulso soportada
Es responsabilidad del cuadrista.
10.9 Propiedades de aislamiento10.9.4 Pruebas de armarios hechos de material aislante
Es responsabilidad del cuadrista.
10.10 Aumento de la temperatura
El cuadrista es responsable del cálculo del aumento de la temperatura. Eaton proporcionará datos de disipación de calor para los dispositivos.
10.11 Resistencia a los cortocircuitos
Es responsabilidad del cuadrista. Deben tenerse en cuenta las especificaciones de la aparamenta.
10.12 Compatibilidad electromagnética
Es responsabilidad del cuadrista. Deben tenerse en cuenta las especificaciones de la aparamenta.
10.13 Función mecánica
El dispositivo cumple los requisitos, siempre que se observe la información del folleto de instrucciones (IL).

Technical data ETIM 7.0

Conmutadores en baja tensión (EG000017) / Contactor de alimentación, conmutación CC (EC002552)
Tecnología electrónica, de automatización y de mando de procesos / Tecnología de conmutación de baja tensión / Contacto (baja tensión) / Power contactor, d.c. switching (ecl@ss10.0.1-27-37-10-18 [ACN974011])
Tensión de alimentación de nominal de control Us a CA 50HZ
110 - 250 Volt
Tensión de alimentación de nominal de control Us a CA 60HZ
110 - 250 Volt
Tensión de alimentación nominal Us en CC
110 - 350 Volt
Tipo de tensión para la activación
CA
Potencia de funcionamiento nominal a CC-3 / CC-5 a 440 V
0 Kilowatt
Intensidad de funcionamiento nominal a CC-3 / CC-5 a 440 V
0 Ampere
Versión modular
No
Número de contactos auxiliares como contacto normalmente abierto
2
Número de contactos auxiliares como contacto normalmente cerrado
2
Tipo de conexión del circuito de corriente principal
Raíl de conexión
Número de contactos normalmente cerrado como contacto principal
0
Número de contactos principales como contacto normalmente abierto
2