168104 SOL30X6-SAFETY-MC4-U(230V50HZ)

General specifications
Product name
Eaton Moeller® series SOL30 Safety Fireman's switch
Part no.
SOL30X6-SAFETY-MC4-U(230V50HZ)
EAN
4015081646814
Product Length/Depth
225 millimetre
Product height
410 millimetre
Product width
500 millimetre
Product weight
9.5 kilogram
Certifications
IEC/EN 60 947-3
Product Tradename
SOL30 Safety
Product Type
Fireman's switch
Product Sub Type
None
Catalog Notes
MC4 connector (Stäubli)
Features & Functions
Actuator type
Turn button
Enclosure material
Plastic
Features
Complete device in housing
Fitted with:
Retraction in 0-position
0 (off) position
Number of poles
Six-pole
General information
Application
Residential buildings
Utility buildings
Connection type
MC4, Inputs
MC4, Outputs
Degree of protection
IP65
Degree of protection (front side)
IP65
NEMA Other
Lifespan, electrical
1,500 Operations
Lifespan, mechanical
100,000 Operations
Model
On/Off switch
Operating frequency
120 Operations/h
Overvoltage category
III
Pollution degree
3
Product Category
Fireman's Switch
Switchgear for photovoltaic systems
Rated impulse withstand voltage (Uimp)
8000 V
Suitable for
Ground mounting
Utilization category
DC-21 A
DC-PV1 (EN 60947-3)
DC-PV2 (EN 60947-3)
Climatic environmental conditions
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
60 °C
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Contacts
Number of auxiliary contacts (change-over contacts)
0
Number of auxiliary contacts (normally closed contacts)
1
Number of auxiliary contacts (normally open contacts)
1
Electrical rating
Rated operational current (Ie)
30 A at AC-21A
30 A at DC-PV1
10 A at DC-PV2
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V
0 A
Rated operational power at AC-3, 380/400 V, 50 Hz
0 kW
Rated operational voltage (Ue) at AC - max
1000 V
Rated uninterrupted current (Iu)
30 A
Resistance
7 mΩ (internal)
Short-circuit rating
Rated short-circuit making capacity (Icm)
0.32 kA (up to 440 V, 50/60 Hz)
Rated short-time withstand current (Icw)
0.36 kA

Technical data ETIM 9.0

Low-voltage industrial components (EG000017) / Off-load switch (EC001105)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Load-break switch (ecl@ss13-27-37-14-05 [AKF062018])
Model
On/Off switch
Number of poles
6
With zero (off) position
Yes
With retraction in 0-position
Yes
Rated permanent current Iu
30 A
Rated operation current Ie at AC-3, 400 V
0 A
Rated operation power at AC-3, 400 V
0 kW
Degree of protection (IP), front side
IP65
Degree of protection (NEMA), front side
Other
Number of auxiliary contacts as normally closed contact
1
Number of auxiliary contacts as normally open contact
1
Number of auxiliary contacts as change-over contact
0
Suitable for floor mounting
Yes
Suitable for front mounting
No
Suitable for distribution board installation
No
Suitable for intermediate mounting
No
Complete device in housing
Yes
Housing material
Plastic
Type of control element
Turn button
Type of electrical connection of main circuit
Screw connection