167608 SPCT2-460/1
Plug-in surge arresters, 1p, 460VAC, 20 kA
EL Number (Norway)
1609771
For protecting consumer systems against transient overvoltages caused by indirect lightning strikes and switching operations, test class II according to IEC 61643-1+A1, SPD-type T2 according to EN 61643-11, SPC-S-HK auxiliary contact for remote signaling can be added, can be bussed with all Xtra Combinations switchgear caused by indirect lightning strikes and switching operations, test class II according to IEC 61643-1+A1, SPD-type T2 according to EN 61643-11, SPC-S-HK auxiliary contact for remote signaling can be added, can be bussed with all Xtra Combinations switchgear
General specifications
Product name
Eaton Moeller series xPole - SPCT2 Surge Protection Device
Part no.
SPCT2-460/1
EAN
4015081640676
Product Length/Depth
80 millimetre
Product height
67 millimetre
Product width
17.5 millimetre
Product weight
0.103 kilogram
Compliances
RoHS conform
Product Tradename
xPole - SPCT2
Product Type
Surge Protection Device
Product Sub Type
None
Delivery program
Application
Open areas
Residential buildings
Utility buildings
Type
Surge arrester
Technical Data - Electrical
Voltage protection level
2.2 kV
Voltage protection level (L-N)
0 kV
Voltage protection level (N-PE)
0 kV
Nominal voltage at AC
460 V
Nominal voltage at DC
0 V
Continuous voltage at AC - max
460 V
Continuous voltage at DC - max
0 V
PV-voltage - max
0 V
Nominal discharge surge current (8/20)
20 kA
Discharge surge current (8/20) - max
40 kA
Short-circuit breaking capacity (ISCCR)
0 kA
Signalling at the device
Optic
Technical Data - Mechanical
Frame
1 modular spacing
Mounting method
DIN rail (top hat rail) 35 mm
Number of conductors without earthing
1
Conductor cross section (flexible, fine-strand) - min
35 mm²
Conductor cross section (flexible, fine-strand) - max
35 mm²
Conductor cross section (solid, solid-strand) - min
25 mm²
Conductor cross section (solid, solid-strand) - max
25 mm²
Degree of protection
IP20
Additional information
Features
Category type 2
System configuration type
Other
TN
TN-S
TN
TN-S
Technical data ETIM 8.0
Earthing, lightning and surge protection (EG000021) / Surge protection device for power supply systems (EC000941)
Electric engineering, automation, process control engineering / Protection installation, device (electric) / Surge protection device (inner lightning protection) / Surge protection device for power supply systems (ecl@ss10.0.1-27-13-08-05 [ACN278011])
System configuration DC
No
System configuration IT
No
System configuration TN
Yes
System configuration TN-C
No
System configuration TN-C-S
No
System configuration TN-S
Yes
System configuration TT
No
System configuration other
Yes
Number of conductors (without earthing)
1
Nominal discharge surge current (8/20)
20 kA
Max. discharge surge current (8/20)
40 kA
Nominal voltage AC
460 V
Nominal voltage DC
0 V
Max. continuous voltage AC
460 V
Max. continuous voltage DC
0 V
Max. PV-voltage
0 V
Voltage protection level
2.2 kV
Voltage protection level L-N
0 kV
Voltage protection level N-PE
0 kV
Max. overcurrent protection device, parallel connection (fuse)
0 A
Max. overcurrent protection device, series connection (fuse)
125 A
Short-circuit breaking capacity (Isccr)
0 kA
Integrated short-circuit protection
No
Integrated short-circuit protection selective to fuse gG
0 A
Integrated backup fuse
No
Leakage-current free
No
Mounting method
DIN rail (top hat rail) 35 mm
Construction size
1 modular spacing
Max. conductor cross section solid (solid, stranded)
25 mm²
Max. conductor cross section flexible (fine-strand)
35 mm²
With remote signalling contact
No
Signalling at the device
Optic
Category type 2
Yes
Degree of protection (IP)
IP20
-