167594 SPCT2-280/2
Plug-in surge arresters, 2p, 280VAC, 2x20kA
Alternate Catalog No.
SPCT2-280/2
EL-Nummer (Norway)
1609766
For protecting consumer systems against transient overvoltages caused by indirect lightning strikes and switching operations, test class II according to IEC 61643-1+A1, SPD-type T2 according to EN 61643-11, SPC-S-HK auxiliary contact for remote signaling can be added, can be bussed with all Xtra Combinations switchgear caused by indirect lightning strikes and switching operations, test class II according to IEC 61643-1+A1, SPD-type T2 according to EN 61643-11, SPC-S-HK auxiliary contact for remote signaling can be added, can be bussed with all Xtra Combinations switchgear
Delivery program
Products
Surge arresters
Application field
Residential buildings
Utility buildings
Open areas
Utility buildings
Open areas
Technical data ETIM 8.0
Earthing, lightning and surge protection (EG000021) / Surge protection device for power supply systems (EC000941)
Electric engineering, automation, process control engineering / Protection installation, device (electric) / Surge protection device (inner lightning protection) / Surge protection device for power supply systems (ecl@ss10.0.1-27-13-08-05 [ACN278011])
System configuration DC
No
System configuration IT
No
System configuration TN
Yes
System configuration TN-C
No
System configuration TN-C-S
No
System configuration TN-S
Yes
System configuration TT
No
System configuration other
Yes
Number of conductors (without earthing)
2
Nominal discharge surge current (8/20)
20 kA
Max. discharge surge current (8/20)
40 kA
Nominal voltage AC
280 V
Nominal voltage DC
0 V
Max. continuous voltage AC
280 V
Max. continuous voltage DC
0 V
Max. PV-voltage
0 V
Voltage protection level
1.4 kV
Voltage protection level L-N
0 kV
Voltage protection level N-PE
0 kV
Max. overcurrent protection device, parallel connection (fuse)
0 A
Max. overcurrent protection device, series connection (fuse)
125 A
Short-circuit breaking capacity (Isccr)
0 kA
Integrated short-circuit protection
No
Integrated short-circuit protection selective to fuse gG
0 A
Integrated backup fuse
No
Leakage-current free
No
Mounting method
DIN rail (top hat rail) 35 mm
Construction size
2 modular spacing
Max. conductor cross section solid (solid, stranded)
25 mm²
Max. conductor cross section flexible (fine-strand)
35 mm²
With remote signalling contact
No
Signalling at the device
Optic
Category type 2
Yes
Degree of protection (IP)
IP20
-
Eaton EMEA Download-Center - download data for this item
-