135690 E58-30RS18-HL
Retroflective sensing sensor, Sn=18m, 4L, 10-30VDC, light, NPN, PNP, M30, metal, line 2m
Alternate Catalog No.
E58-30RS18-HL
E58 series, product features: sensors with a diameter of 18 mm or 30 mm.Highly refined optics for long sensing ranges and to see through high levels of contamination – unmatched optical performance. Resistant to many chemicals used in the automotive, food processing and forest products industries. Suitable for high temperature, high pressure washdown (82 bar). mechanical Viton gaskets are resistant to extreme temperature variations. visible sensing beam on all models lets you see where the beam is aimed for quick flush mounting and alignment. The function display is the brightest available and is visible from any angle and in any lighting condition. The industry’s only background suppression sensors with a 2-wire circuit design. 4-wire DC sensors feature an PNP and a NPN output
Delivery program
Basic function
Optical sensors
Product range
E58 Harsh Duty Series
For connection of:
2 m connection cable
Design (outer dimensions)
M30 x 1.5 mm
Rated operational voltage [Ue]
10 - 30 V DC
Rated switching distance [Sn
]
18000 mm
Description
for combination with reflector
Connection
4-wire
Function
Reflex photoelectric sensor
Type of light
Visible red
Material
Stainless steel
Switching type
NPN
PNP
PNP
Switching principle
Light switching
Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-5-2; CE marking
UL File No. E166051
UL Category Control No. NRKH, NRKH7
CSA File No. UL report applies to both Canada and US
CSA Class No. –
North America Certification UL listed, certified by UL for use in Canada
Max. Voltage Rating 30 V DC
Degree of Protection IEC: IP68, IP69K; UL/CSA Type: 1, 2, 3, 3R, 3S, 4, 4x, 6, 6P, 12, 12K, 13
Technical data
General
Standards
IEC/EN 60947-5-2
Ambient temperature
-40 - +55
Mechanical shock resistance
100
Shock duration 3 ms g
Shock duration 3 ms g
Degree of Protection
IP69
Characteristics
Rated switching distanceRated switching distance [Sn
]
18000 mm
Range
18 mm
Rated operational voltage [Ue]
10 - 30 V DC
Maximum load current [Ie
]
< 100 mA
Response time
1.6 ms
Switching state display
Red LED
Protective functions
Short-circuit protective device
Protection against polarity reversal
Protection against wire breakage
Protection against polarity reversal
Protection against wire breakage
Connection
4-wire
StyleDesign (outer dimensions)
M30 x 1.5 mm
For connection of:
2 m connection cable
Material
Stainless steel
Design verification as per IEC/EN 61439
Operating ambient temperature min.
-40 °C
Operating ambient temperature max.
+55 °C
Technical data ETIM 8.0
Sensors (EG000026) / Retroreflective photoelectric sensor (EC002717)
Electric engineering, automation, process control engineering / Binary sensor technology, safety-related sensor technology / Optoelectronic sensor / Reflection light barrier (ecl@ss10.0.1-27-27-09-02 [AKP251013])
Pre failure notice
No
With time function
No
Rated switching distance
18000 mm
Max. switching distance
0 mm
Max. output current
100 mA
With reflector
No
Analogue output 0 V ... 10 V
No
Analogue output 0 mA ... 20 mA
No
Analogue output 4 mA ... 20 mA
No
Analogue output -10 V ... +10 V
No
With other analogue output
No
Setting procedure
Other
With communication interface analogue
No
With communication interface AS-Interface
No
With communication interface CANOpen
No
With communication interface DeviceNet
No
With communication interface Ethernet
No
With communication interface INTERBUS
No
With communication interface PROFIBUS
No
With communication interface RS-232
No
With communication interface RS-422
No
With communication interface RS-485
No
With communication interface SSD
No
With communication interface SSI
No
Number of semiconductor outputs with signalling function
2
Number of contact energized outputs with signalling function
0
Number of protected semiconductor outputs
0
Number of protected contact energized outputs
0
Type of interface for safety communication
Other
Type of electric connection
Cable
Type of switching output
NPN
Type of switch function
Other
Operation agent-safety class
Explosion safety category for gas
None
Explosion safety category for dust
None
Construction type housing
Cuboid
Width sensor
0 mm
Diameter sensor
30 mm
Height of sensor
0 mm
Length of sensor
111 mm
Sensing mode
Light switching
Material of optical surface
Glass
Material housing
Metal
Max. output current at protected output
0 mA
Min. reflector distance
0 mm
Ambient temperature
-40 - 55 °C
Response time
ms
Transmission range of the safety field
0 m
Switching frequency
312 Hz
Type of safety according to IEC 61496-1
1
Switching voltage of OSSD at state "high"
30 V
Rated control supply voltage Us at AC 50HZ
0 - 0 V
Rated control supply voltage Us at AC 60HZ
0 - 0 V
Rated control supply voltage Us at DC
10 - 30 V
Voltage type
DC
With monitoring function downstream switching devices
No
Laser protection class
None
Wavelength of the sensor
0 nm
Type of light
Other
Light dot
0 mm²
With restart blockage
No
Suitable for safety functions
No
Degree of protection (IP)
IP67
Degree of protection (NEMA)
6P, 13
Approvals
Product Standards
UL 508; CSA-C22.2 No. 14; IEC60947-5-2; CE marking
UL File No.
E166051
UL Category Control No.
NRKH, NRKH7
CSA File No.
UL report applies to both Canada and US
CSA Class No.
–
North America Certification
UL listed, certified by UL for use in Canada
Max. Voltage Rating
30 V DC
Degree of Protection
IEC: IP68, IP69K; UL/CSA Type: 1, 2, 3, 3R, 3S, 4, 4x, 6, 6P, 12, 12K, 13
-
Eaton EMEA Download-Center - download data for this item
-
Eaton EMEA Download-Center