Delivery program

Product range
SmartWire-DT accessories
Basic function
Network terminator
Function
For the SmartWire-DT bus termination on the SmartWire-DT ribbon cable
Description
SmartWire-DT bus termination; plugged onto SWD4-8MF2 blade terminal at the end of the SmartWire-DT ribbon cable
Connection to SmartWire-DT
yes
For use with
SWD4-…LF8-24…
For use with
for 8 pole ribbon cable
Protection type (IEC/EN 60529, EN50178, VBG 4)
IP20

Technical data

General
Standards
IEC/EN 61131-2
EN 50178
Dimensions (W x H x D)
48.5 x 34.5 x 10 mm
Weight
0.01 kg
Mounting position
As required
Power loss [P]
0.4 W
Ambient conditions, mechanical
Protection type (IEC/EN 60529, EN50178, VBG 4)
IP20
Vibrations (IEC/EN 61131-2:2008)Constant amplitude 3,5 mm constant amplitude 0.15 mm max.
8.4 Hz
Vibrations (IEC/EN 61131-2:2008)Constant amplitude 3,5 mm constant amplitude 0.15 mm minim.
5 Hz
Vibrations (IEC/EN 61131-2:2008)Constant acceleration 1 gconstant acceleration 1 g max.
150 Hz
Vibrations (IEC/EN 61131-2:2008)Constant acceleration 1 gconstant acceleration 1 g min.
8.4 Hz
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms
9 Impacts
Drop to IEC/EN 60068-2-31 [Drop height]
50 mm
Free fall, packaged (IEC/EN 60068-2-32)
0.3 m
Electromagnetic compatibility (EMC)
Overvoltage category
II
Pollution degree
2
Electrostatic discharge (IEC/EN 61131-2:2008)Air discharge (Level 3)
8 kV
Electrostatic discharge (IEC/EN 61131-2:2008)Contact discharge (Level 2)
4 kV
Electromagnetic fields (IEC/EN 61131-2:2008)2 - 2.7 GHz
1 V/m
Electromagnetic fields (IEC/EN 61131-2:2008)1.4 - 2 GHz
3 V/m
Electromagnetic fields (IEC/EN 61131-2:2008)80 - 1000 MHz
10 V/m
Radio interference suppression
Class A
Burst (IEC/EN 61131-2:2008, Level 3)SmartWire-DT cables
1 kV
Radiated RFI (IEC/EN 61131-2:2008, Level 3)
10 V
Climatic environmental conditions
Climatic proofing
Dry heat to IEC 60068-2-2
Damp heat as per EN 60068-2-3
Air pressure (operation)
795 - 1080 hPa
Ambient temperatureOperation [ϑ]
-25 - +55 °C
Ambient temperatureStorage / Transport [ϑ]
-40 - +70 °C
Ambient temperatureRelative humidityCondensation
Take appropriate measures to prevent condensation
Ambient temperatureRelative humidityRelative humidity, non-condensing (IEC/EN 60068-2-30)
5 - 95 %
Connection options
Connection 1
Plug, 8-pole
Number of insertion cycles
≥ 200
Current consumption
17 mA

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
0 A
Heat dissipation per pole, current-dependent [Pvid]
0 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
0.4 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+55 °C
Degree of Protection
IP20
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

PLC's (EG000024) / Accessories for controls (EC002584)
Electric engineering, automation, process control engineering / Control / Programmable logic control (SPS) / Programmable logic control (SPS, accessories) (ecl@ss10.0.1-27-24-22-92 [AFR333003])
Type of electrical accessory
Plug
Type of mechanical accessory
Cover

Approvals

UL File No.
E29184
UL Category Control No.
NKCR
CSA File No.
2324643
CSA Class No.
3211-07
North America Certification
UL listed, CSA certified
Specially designed for North America
No

Dimensions

2723DIM-13
Bus termination
Bus termination