General specifications
Product name
Eaton xComfort BC version A
Part no.
BC-A-3/39-TW
EAN
4015081014521
Product Length/Depth
480 millimetre
Product height
145 millimetre
Product width
260 millimetre
Product weight
1.8 kilogram
Compliances
RoHS conform
Product Tradename
xComfort BC
Product Type
Version A
Product Sub Type
None
Delivery program
Color
White
Technical Data - Mechanical
Closure type
Other
Enclosure material
Plastic
Width in number of modular spacings
13
Mounting method
Surface mounted (plaster)
DIN-rail
Degree of protection
IP40
Number of rows
3
Built-in depth
46 mm
Built-in height
0 mm
Built-in width
234 mm
Internal depth
72 mm
Cover/door model
With notch
Cover/door type
Single
Door
Temperature-rise verification as per IEC 60890
Heat diss. ambient 35°C delta T:20°C wall mount individ. encl. top (IEC 60890)
20 W
Heat diss. ambient 35°C delta T:35°C wall mount individ. encl. top (IEC 60890)
41 W
Design verification as per IEC/EN 61439
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
650 °C; meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Not relevant to indoor installations.
10.2.5 Lifting
Does not apply to enclosures without lifting aids.
10.2.6 Mechanical impact
IK07
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
IP40
10.4 Clearances and creepage distances
Is the panel builder's responsibility.
10.5 Protection against electric shock
Protection class 2, therefore not applicable.
10.6 Incorporation of switching devices and components
Is the panel builder's responsibility.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Ui = 440 V AC
10.9.3 Impulse withstand voltage
4 kV
10.9.4 Testing of enclosures made of insulating material
Meets the product standard's requirements.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
Meets the product standard's requirements.
Additional information
RAL-number
9010

Technical data ETIM 9.0

Distribution boards (EG000023) / Small distribution board (EC000214)
Electric engineering, automation, process control engineering / Electrical installation, device / Electrical distribution system (including small distribution board) / Small distribution board (ecl@ss13-27-14-24-09 [ACN387016])
Mounting method
Surface mounted
Number of rows
3
Width in number of modular spacings
13
Type of covering
Door
Cover model
With notch
Type of door
Single
Transparent cover/door
No
Signal passing door
No
With lock
No
Type of closure
Other
Housing material
Plastic
Built-in depth
46 mm
Built-in height
0 mm
Built-in width
234 mm
Inner depth
72 mm
Earthing terminal block
No
Neutral terminal block
No
DIN-rail
Yes
With mounting plate
No
Extension possible
No
EMC-version
No
UV resistant
No
Colour
White
RAL-number
9010
Degree of protection (IP)
IP40
Height
145 mm
Width
260 mm
Depth
480 mm