Delivery program

Rated operational current [Ie ]
AC-15240 V [Ie]
2 A
AC-15415 V [Ie]
2 A
DCNotes
Switch-on and switch-off conditions based on DC-13, time constant as specified.
DCDC-13 L/R - 300 ms220 V [Ie]220 V [Ie ]
0.03 A
Actuating voltage [Us]
24 V DC
Actuating current [I]
25 mA
Contact sequence
210S025
For use with
DILM...
DILMP...
DILL...
DILK...
DILMF…As required
Description
Input with built-in suppressor circuit for overvoltage limitation
Instructions
Contactor coils with rated operational current > 2 A must be actuated via the DILER-G mini contactor relay.

Technical data

General
Standards
IEC/EN 60947, VDE 0660, UL, CSA
Lifespan, mechanicalDC operated [Operations]
30 x 106
Maximum operating frequencyDC operated [Operations]
72000 x 106
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperatureOpen
-25 - +60 °C
Ambient temperatureEnclosed
- 25 - 45 °C
Mounting position
As required
Mechanical shock resistance (IEC/EN 60068-2-27)Half-sinusoidal shock, 20 msN/O contact
10 g
Degree of Protection
IP20
Protection against direct contact when actuated from front (EN 50274)
Finger and back-of-hand proof
Weight
0.09 kg
Terminal capacitiesNotes
Only use equal cross-sections.
Terminal capacitiesSolid
1 x (0.75 - 2.5)
2 x (0.75 - 2.5) mm2
Terminal capacitiesFlexible with ferrule
1 x (0.75 - 2.5)
2 x (0.75 - 1.5) mm2
Terminal capacitiesSolid or stranded
16 - 14 AWG
Terminal screw
M3.5
Pozidriv screwdriver
2 Size
Standard screwdriver
0.8 x 5.5
1 x 6 mm
Max. tightening torque
1.2 Nm
Contacts
Rated impulse withstand voltage [Uimp]
6000 V AC
Overvoltage category/pollution degree
III/2
Rated insulation voltage [Ui]
440 V AC
Rated operational voltage [Ue ]
440 AC V
Rated operational current [Ie ]AC-15220 V 230 V 240 V [Ie]
2 A
Rated operational current [Ie ]AC-15380 V 400 V 415 V [Ie]
2 A
Rated operational current [Ie ]DC-13 DC-13 L/R - 15 msContacts in series:1 [24 V]
2.6 A
Rated operational current [Ie ]DC-13 DC-13 L/R - 15 msContacts in series:1 [60 V]
1 A
Rated operational current [Ie ]DC-13 DC-13 L/R - 15 msContacts in series:1 [110 V]
0.6 A
Rated operational current [Ie ]DC-13 DC-13 L/R - 15 msContacts in series:1 [220 V]
0.2 A
Rated operational current [Ie ]DC-13 DC L/R ≦ 50 msContacts in series:1 [24 V]
2 A
Rated operational current [Ie ]DC-13 DC L/R ≦ 50 msContacts in series:1 [60 V]
0.6 A
Rated operational current [Ie ]DC-13 DC L/R ≦ 50 msContacts in series:1 [110 V]
0.08 A
Rated operational current [Ie ]DC-13 DC L/R ≦ 50 msContacts in series:1 [220 V]
0.08 A
Rated operational current [Ie ]DC-13 DC-13 L/R - 300 msContacts in series:1 [24 V]
0.6 A
Rated operational current [Ie ]DC-13 DC-13 L/R - 300 msContacts in series:1 [60 V]
0.2 A
Rated operational current [Ie ]DC-13 DC-13 L/R - 300 msContacts in series:1 [110 V]
0.08 A
Rated operational current [Ie ]DC-13 DC-13 L/R - 300 msContacts in series:1 [220 V]
0.03 A
Control circuit reliability [Failure rate]
<10-8, < one failure at 100 million operations
(at Ue = 24 V DC, Umin = 17 V, Imin = 5.4 mA) λ
Conventional thermal current [Ith ]
6 A
Component lifespanAC-15230 V, Ie = 0.1 A [Operations]
7 x 106
Component lifespanAC-15230 V, Ie = 1.2 A [Operations]
1 x 106
Short-circuit rating without weldingShort-circuit protection maximum fuse500 V
4 A fast
Magnet systems
Voltage tolerancePick-up voltageDC operated [Pick-up] [Pick-up]
0.85 - 1.2 x Uc
Power consumptionDC operated [Pull-in = sealing]
0.6 W
duty factor
100 % DF
Changeover time at 100 % US (recommended value)DC operated closing delaySwitching times, DC operated, max. closing delay
7 ms
Changeover time at 100 % US (recommended value)DC operated, opening delay
3 ms
Notes
Notes
For rated operational current: Making and breaking conditions to DC-13, L/R constant as stated
Max. fuses for short-circuit protection: Transparent overlay "Fuses" for time/current characteristics (please enquire)
For pick-up voltage, DC operated:Pure DC, AC bridge rectifier or smoothed double-wave rectification.
For connection cross section: only use equal cross-sections
Rating data for approved types
Auxiliary contactsPilot DutyAC operated
B300

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
0 A
Heat dissipation per pole, current-dependent [Pvid]
0 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
0.47 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+60 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Contactor relay (EC000196)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Contactor (LV) / Contactor relay (ecl@ss10.0.1-27-37-10-01 [AAB716014])
Rated control supply voltage Us at AC 50HZ
0 - 0 V
Rated control supply voltage Us at AC 60HZ
0 - 0 V
Rated control supply voltage Us at DC
24 - 24 V
Voltage type for actuating
DC
Rated operation current Ie, 400 V
2 A
Connection type auxiliary circuit
Screw connection
Mounting method
DIN rail
Interface
No
Number of auxiliary contacts as normally closed contact
1
Number of auxiliary contacts as normally open contact
1
Number of auxiliary contacts as normally closed contact, delayed switching
0
Number of auxiliary contacts as normally open contact, leading
0
With LED indication
Yes
Number of auxiliary contacts as change-over contact
0
Manual operation possible
No

Approvals

Product Standards
IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking
UL File No.
E29184
UL Category Control No.
NKCR
CSA File No.
012528
CSA Class No.
2411-03, 3211-04
North America Certification
UL listed, CSA certified
Specially designed for North America
No

Dimensions