General specifications
Product name
Eaton xEffect K-Type Terminal Enclosures Switch- & Controlgear Enclosure
Part no.
K3X185/5
EAN
4015080701040
Product Length/Depth
125 millimetre
Product height
140 millimetre
Product width
366 millimetre
Product weight
12.939 kilogram
Compliances
RoHS conform
Product Tradename
xEffect K-Type Terminal
Product Type
Enclosures
Product Sub Type
Switch- & Controlgear Enclosure
Delivery program
Type
Accessory panel building
General switchboard accessory
Accessory/spare part type
Terminals, 160 – 1000 A
Terminations
Nominal current
800 A
Number of poles
Five-pole
Technical Data - Electrical
Rated insulation voltage (Ui)
1000 V AC
Rated operation current (Ie)
800 A
Technical Data - Mechanical
Mounting method
Screw
Number of connections (10 mm squared)
0
Number of connections (16 mm squared)
0
Number of connections (25 mm squared)
0
Number of connections (250 kcmil)
0
Number of connections (< 6 mm squared)
0
Number of connections (< AWG 6)
0
Number of connections (> 25 mm squared)
10
Number of connections (> 250 kcmil)
0
Number of connections (AWG 2)
0
Number of connections (AWG 4)
0
Number of connections (AWG 4/0)
0
Number of connections (AWG 6)
0
Number of connections (total)
10
Number of inputs
2
Number of outputs
3
Connection type
Clamp
Screwing
Terminal capacity (aluminum cable)
150 mm² - 185 mm² (2x)
95 mm² - 150 mm² (3x)
Terminal capacity (conductor)
50 mm x 20 mm
Terminal capacity (copper band)
2 segments of 21 mm x 1 mm (11x) for flat strip
Terminal capacity (copper/aluminum cable)
50 mm² - 185 mm² (3x)
120 mm² - 240 mm² (2x)
Conductor cross section, input - min
50 mm²
Conductor cross section, input - max
185 mm²
Conductor cross section, input AWG - min
1 mm²
Conductor cross section, input AWG - max
350 mm²
Conductor cross section, output - min
50 mm²
Conductor cross section, output - max
300 mm²
Conductor cross section, output AWG - min
0 mm²
Conductor cross section, output AWG - max
0 mm²
Additional information
Features
Contact safe
Special features
Conversion kits for strip terminal in cable connection available separately
Terminal covers available separately
Including labels for terminal marking U, V, W - X, Y, Z - L1, L2, L3 - T1, T2, T3 - PE, N, PEN, protective earth (ground) symbol
Relationship of rated operational current →terminal capacity to IEC/EN 60439, VDE 0660 Part 500 or EN 50021
Outer terminal for round or sectoral conductor, other side for Cu strip
Suitable for
Useful for stranded conductors
Used with
General switchboard accessory
Accessory panel building

Technical data ETIM 9.0

Energy distribution systems (EG000015) / Main line branch terminal (EC000275)
Electric engineering, automation, process control engineering / Electrical insulation and connecting material / Energy distribution system / Rail terminal bar clamp (ecl@ss13-27-40-06-03 [ACO369016])
Number of poles
5
Nominal current
800 A
Connection type
Screwing
Mounting method
Screw
Number of inputs
2
Number of outputs
3
Suitable for solid conductors
No
Suitable for stranded conductors
Yes
Suitable for fine strand conductors
No
Suitable for fine strand conductors without cable end sleeve
No
Suitable for extra fine-strand conductors
No
Suitable for extra fine-strand conductors without cable end sleeve
No
Conductor cross section, input
50 - 185 mm²
Conductor cross section, output
50 - 300 mm²
Conductor cross section, input AWG
1 - 350
Conductor cross section, output AWG
0 - 0
Contact safe
Yes
Height
140 mm
Width
366 mm
Depth
125 mm