041628 K240/4
Connection terminal, 400A, 4p, flat/round
K connecting terminals, for AL and CU, one side round and the other side flat, rated operational current Ie=400 A, poles=4, terminal capacities: Copper round cable stranded, sectoral stranded, round cable solid, sectoral solid, round cable solid, sectoral solid=1x50-240 or 2x25-120mm² or aluminum, sectoral solid=1x95-185 or 2x50-95mm². Other side: copper band 6x16x0.8 to 10x16x0.8 or Cu bar=25x15 mm, notes: Conversion kits for strip terminal in cable connection available separately, terminal covers available separately
General specifications
Product name
Eaton xEffect K-Type Terminal Enclosures Switch- & Controlgear Enclosure
Part no.
K240/4
EAN
4015080416289
Product Length/Depth
100 millimetre
Product height
115 millimetre
Product width
190 millimetre
Product weight
3.608 kilogram
Compliances
RoHS conform
Product Tradename
xEffect K-Type Terminal
Product Type
Enclosures
Product Sub Type
Switch- & Controlgear Enclosure
Delivery program
Type
Accessory panel building
General switchboard accessory
General switchboard accessory
Accessory/spare part type
Terminations
Terminals, 160 – 1000 A
Terminals, 160 – 1000 A
Nominal current
400 A
Number of poles
Four-pole
Technical Data - Electrical
Rated insulation voltage (Ui)
1000 V AC
Rated operation current (Ie)
400 A
Technical Data - Mechanical
Mounting method
Screw
Number of connections (10 mm squared)
0
Number of connections (16 mm squared)
0
Number of connections (25 mm squared)
0
Number of connections (250 kcmil)
0
Number of connections (< 6 mm squared)
0
Number of connections (< AWG 6)
0
Number of connections (> 25 mm squared)
8
Number of connections (> 250 kcmil)
0
Number of connections (AWG 2)
0
Number of connections (AWG 4)
0
Number of connections (AWG 4/0)
0
Number of connections (AWG 6)
0
Number of connections (total)
8
Number of inputs
1
Number of outputs
2
Connection type
Clamp
Screwing
Screwing
Terminal capacity (aluminum cable)
50 mm² - 95 mm² (2x)
95 mm² - 185 mm² (1x)
95 mm² - 185 mm² (1x)
Terminal capacity (conductor)
25 mm x 15 mm
Terminal capacity (copper band)
16 mm x 0.8 mm (10x) for flat strip
16 mm x 0.8 mm (6x) for flat strip
16 mm x 0.8 mm (6x) for flat strip
Terminal capacity (copper/aluminum cable)
50 mm² - 240 mm² (1x)
25 mm² - 120 mm² (2x)
25 mm² - 120 mm² (2x)
Conductor cross section, input - min
25 mm²
Conductor cross section, input - max
240 mm²
Conductor cross section, input AWG - min
4 mm²
Conductor cross section, input AWG - max
500 mm²
Conductor cross section, output - min
25 mm²
Conductor cross section, output - max
240 mm²
Conductor cross section, output AWG - min
0 mm²
Conductor cross section, output AWG - max
0 mm²
Additional information
Features
Contact safe
Special features
Conversion kits for strip terminal in cable connection available separately
Terminal covers available separately
Including labels for terminal marking U, V, W - X, Y, Z - L1, L2, L3 - T1, T2, T3 - PE, N, PEN, protective earth (ground) symbol
Relationship of rated operational current →terminal capacity to IEC/EN 60439, VDE 0660 Part 500 or EN 50021
Outer terminal for round or sectoral conductor, other side for Cu strip
Terminal covers available separately
Including labels for terminal marking U, V, W - X, Y, Z - L1, L2, L3 - T1, T2, T3 - PE, N, PEN, protective earth (ground) symbol
Relationship of rated operational current →terminal capacity to IEC/EN 60439, VDE 0660 Part 500 or EN 50021
Outer terminal for round or sectoral conductor, other side for Cu strip
Suitable for
Fine strand conductors
Useful for stranded conductors
Useful for stranded conductors
Used with
Accessory panel building
General switchboard accessory
General switchboard accessory
Technical data ETIM 8.0
Energy distribution systems (EG000015) / Rail terminal bar (EC000275)
Tecnología electrónica, de automatización y de mando de procesos / Material de aislamiento y de conexiones eléctricas / Energy distribution system / Rail terminal bar clamp (ecl@ss10.0.1-27-40-06-03 [ACO369011])
Number of poles
4
Nominal current
400 A
Connection type
Screwing
Mounting method
Screw
Number of inputs
1
Number of outputs
2
Suitable for solid conductors
No
Suitable for stranded conductors
Yes
Suitable for fine strand conductors
Yes
Suitable for fine strand conductors without cable end sleeve
No
Suitable for extra fine-strand conductors
No
Suitable for extra fine-strand conductors without cable end sleeve
No
Conductor cross section, input
25 - 240 mm²
Conductor cross section, output
mm²
Conductor cross section, input AWG
4 - 500 mm²
Conductor cross section, output AWG
0 - 0 mm²
Contact safe
Yes
Height
115 mm
Width
190 mm
Depth
100 mm
-
Asset
-
Asset
-
Eaton EMEA Download-Center - download data for this item
-
Eaton EMEA Download-Center