General specifications
Product name
Eaton xEffect K-Type Terminal Enclosures Switch- & Controlgear Enclosure
Part no.
K150/4
EAN
4015080345091
Product Length/Depth
100 millimetre
Product height
115 millimetre
Product width
130 millimetre
Product weight
2.35 kilogram
Compliances
RoHS conform
Product Tradename
xEffect K-Type Terminal
Product Type
Enclosures
Product Sub Type
Switch- & Controlgear Enclosure
Delivery program
Type
Accessory panel building
General switchboard accessory
Accessory/spare part type
Terminals, 160 – 1000 A
Terminations
Nominal current
250 A
Number of poles
Four-pole
Technical Data - Electrical
Rated insulation voltage (Ui)
1000 V AC
Rated operation current (Ie)
250 A
Technical Data - Mechanical
Mounting method
Screw
Number of connections (10 mm squared)
0
Number of connections (16 mm squared)
0
Number of connections (25 mm squared)
0
Number of connections (250 kcmil)
0
Number of connections (< 6 mm squared)
0
Number of connections (< AWG 6)
0
Number of connections (> 25 mm squared)
8
Number of connections (> 250 kcmil)
0
Number of connections (AWG 2)
0
Number of connections (AWG 4)
0
Number of connections (AWG 4/0)
0
Number of connections (AWG 6)
0
Number of connections (total)
8
Number of inputs
1
Number of outputs
2
Connection type
Clamp
Screwing
Terminal capacity (aluminum cable)
35 mm² - 50 mm² (2x)
50 mm² - 120 mm² (1x)
Terminal capacity (conductor)
18 mm x 4 mm
Terminal capacity (copper band)
1 segment of 16 mm x 0.8 mm (4x) - 2 segments of 16 mm x 0.8 mm (6x) for flat strip
Terminal capacity (copper/aluminum cable)
35 mm² - 150 mm² (1x)
16 mm² - 70 mm² (2x)
Conductor cross section, input - min
16 mm²
Conductor cross section, input - max
150 mm²
Conductor cross section, input AWG - min
6 mm²
Conductor cross section, input AWG - max
300 mm²
Conductor cross section, output - min
16 mm²
Conductor cross section, output - max
150 mm²
Conductor cross section, output AWG - min
0 mm²
Conductor cross section, output AWG - max
0 mm²
Additional information
Features
Contact safe
Special features
Conversion kits for strip terminal in cable connection available separately
Terminal covers available separately
Including labels for terminal marking U, V, W - X, Y, Z - L1, L2, L3 - T1, T2, T3 - PE, N, PEN, protective earth (ground) symbol
Relationship of rated operational current →terminal capacity to IEC/EN 60439, VDE 0660 Part 500 or EN 50021
Outer terminal for round or sectoral conductor, other side for Cu strip
Suitable for
Useful for stranded conductors
Used with
Accessory panel building
General switchboard accessory

Technical data ETIM 8.0

Energy distribution systems (EG000015) / Rail terminal bar (EC000275)
Electric engineering, automation, process control engineering / Electrical insulation and connecting material / Energy distribution system / Rail terminal bar clamp (ecl@ss10.0.1-27-40-06-03 [ACO369011])
Number of poles
4
Nominal current
250 A
Connection type
Screwing
Mounting method
Screw
Number of inputs
1
Number of outputs
2
Suitable for solid conductors
No
Suitable for stranded conductors
Yes
Suitable for fine strand conductors
No
Suitable for fine strand conductors without cable end sleeve
No
Suitable for extra fine-strand conductors
No
Suitable for extra fine-strand conductors without cable end sleeve
No
Conductor cross section, input
16 - 150 mm²
Conductor cross section, output
mm²
Conductor cross section, input AWG
6 - 300 mm²
Conductor cross section, output AWG
0 - 0 mm²
Contact safe
Yes
Height
115 mm
Width
130 mm
Depth
100 mm