General specifications
Product name
Eaton xEffect Ci Enclosures Switch- & Controlgear Enclosure
Part no.
D200-CI48/2T-NA
EAN
4015080123927
Product Length/Depth
180 millimetre
Product height
750 millimetre
Product width
375 millimetre
Product weight
3.4 kilogram
Compliances
RoHS conform
Product Tradename
xEffect Ci
Product Type
Enclosures
Product Sub Type
Switch- & Controlgear Enclosure
Delivery program
Type
Basic enclosure
Enclosure cover for North America
xEnergy Safety Ci
Accessory/spare part type
Enclosure cover with door
Color
Other
Technical Data - Mechanical
Unit type
Modular system
Surface finishing
Untreated
Mounting depth
200 mm
Material
Plastic
Degree of protection
IP65
Cover/door type
Transparent, smoky gray
Suitable for enclosure building length/depth
0 mm
Suitable for enclosure building width
0 mm
Temperature-rise verification as per IEC 60890
Heat diss. ambient 35°C delta T: 20°C wall mount middle encl. top (IEC 60890)
32 W
Heat diss. ambient 35°C delta T: 35°C wall mount middle encl. top (IEC 60890)
64 W
Heat diss. ambient 35°C delta T:20°C wall mount individ. encl. top (IEC 60890)
35 W
Heat diss. ambient 35°C delta T:20°C wall mount starting encl. top (IEC 60890)
33 W
Heat diss. ambient 35°C delta T:35°C wall mount individ. encl. top (IEC 60890)
70 W
Heat diss. ambient 35°C delta T:35°C wall mount starting encl. top (IEC 60890)
67 W
Design verification as per IEC/EN 61439
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
850 °C; meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Not relevant to indoor installations.
10.2.5 Lifting
40 kg per enclosure with support frame and lifting aid met, assembled and secured as per the latest applicable instruction leaflet.
10.2.6 Mechanical impact
IK10
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
IP65, with base unit
10.4 Clearances and creepage distances
Is the panel builder's responsibility.
10.5 Protection against electric shock
Protection class 2, therefore not applicable.
10.6 Incorporation of switching devices and components
Is the panel builder's responsibility.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Ui = 1000 V AC
10.9.3 Impulse withstand voltage
8 kV
10.9.4 Testing of enclosures made of insulating material
Meets the product standard's requirements.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
Meets the product standard's requirements.
Additional information
Functions
Basic enclosure
RAL-number
0
Suitable for
Outdoor set-up
Used with
U-CI48…
xEnergy Safety Ci
Enclosure cover for North America
Basic enclosure

Technical data ETIM 9.0

Cabinet enclosures (EG000011) / Top-/floor element (enclosure/cabinet) (EC000744)
Electric engineering, automation, process control engineering / Electrical cabinet, housing, rack / Roof element (electrical cabinet) / Top cover/top cover element (electrical cabinet ) (ecl@ss13-27-18-24-05 [ACN616016])
Suitable for roof planking
No
Suitable for bottom planking
No
Width
375 mm
Height
750 mm
Depth
180 mm
Suitable for enclosure building width
0 mm
Suitable for enclosure building depth
0 mm
Material
Plastic
Surface finishing
Untreated
Colour
Other
RAL-number
0
With de-aeration
No
Suitable for outdoor set-up
Yes
With cable entry
No